Full Automatic Hematology Analyzer
37 blood report parameters
7 body fluid report parameters
83 samples / hour
Data Storage Capacity At least 500, 000 results
Product Brochure:DOWNLOAD
- Introduction
- Parameter
Introduction
YJ-7200 Plus Automatic Hematology System
Parameter:
37 blood report parameters:
WBC, NEU%, LYM%,MON%,EOS%, BAS%, NEU#, LYM#, MON#,EOS#, BAS#,IG#,IG%,RBC,HGB,MCV, HCT, MCH,MCHC,RDW-SD, RDW-CV, NRBC%,NRBC#, PLT,
MPV, PCT PDW,P-LCR, P-LCC, RET%,RET#,IRF LFR,MFR,HFR,RHE,IPF
7 body fluid report parameters:
WBC-BF TC-BF#MN#,MN%,PMN#,PMN% RBC-BF Test Principle Cyanide-free colorimetry for HGB test Sheath impedance method for RBC and PLT
test Semiconductor laser flow cytometry for WBCRBCNRBC test Throughput CBC+DIFF: 120 samples / hour CBC+DIFF+RET:83 samples / hour
BF: 40 samples / hour Data Storage Capacity At least 500, 000 results Data System RJ45 networkinterface.USB interfacecan be
connected to LIS/HIS
37 blood report parameters:
WBC, NEU%, LYM%,MON%,EOS%, BAS%, NEU#, LYM#, MON#,EOS#, BAS#,IG#,IG%,RBC,HGB,MCV, HCT, MCH,MCHC,RDW-SD, RDW-CV, NRBC%,NRBC#, PLT,
MPV, PCT PDW,P-LCR, P-LCC, RET%,RET#,IRF LFR,MFR,HFR,RHE,IPF
7 body fluid report parameters:
WBC-BF TC-BF#MN#,MN%,PMN#,PMN% RBC-BF Test Principle Cyanide-free colorimetry for HGB test Sheath impedance method for RBC and PLT
test Semiconductor laser flow cytometry for WBCRBCNRBC test Throughput CBC+DIFF: 120 samples / hour CBC+DIFF+RET:83 samples / hour
BF: 40 samples / hour Data Storage Capacity At least 500, 000 results Data System RJ45 networkinterface.USB interfacecan be
connected to LIS/HIS
Parameter
Advanced Platform
|
Nucleic acid fluorescence staining integrated with semiconductor laser flow cytometrySide fluorescent light (SFL)
* Nucleic acid content of cells Side scatter {SSC) *Internal cell structure Forward scatter (FSC) * Cell volume information |
Multiple Test Modes
|
2.Multiple Test Modes
5 sample analysis modes and 5 test modes can be chosen freely Analysis mode: Automatic whole blood mode, Whole bloodmode, Pre-dilute mode, Micro-WB mode, Body Fluid modeDetection mode: CBC, CBC+DIFF RET, CBC+DIFF+RET, CBC+RET Body fluid mode Supporting body fluid test by providing 7 reportable parameters(WBC-BF, TC-BF#, MN#, MN%, PMN#, PMN%, RBC-BF) |
New Breakthrough
|
Automatic recheck function
When the automatic recheck function is enabled, the sample will be automatically rechecked when the PLT and WBC count values are lower than the set threshold to reduce the microscopy rate. Low value WBC detection function |
Flexible Combination
|
Free combination of 1-4 modules, measuring speed can be up to 480 test/hour, meeting the requirements of large and medium-sized
laboratories for large volume testing. Supporting pre-storage and collecting tray, expanding sample positions up to 520, improving test efficiency of batch test. |