All Categories
DR X-ray System

Home /  Products  /  X-ray Series  /  DR X-ray System

500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine
500mA Digital X- Ray Machine

500mA Digital X- Ray Machine

1.YJ-X501 Digital X-Ray Radiography Machine.

2.The main components:HV Generator,X Ray Tube Radiography,Table,Bucky Stand,HVCable,Collimator, The Electrical Box.

Product Brochure:DOWNLOAD

  • Video
  • Introduction
  • Parameter
Video

Introduction

1 .YJ-X501 Digital X-Ray Radiography Machine is mainly used for medical examinations of human breasts, limbs, pelvis and lumbar vertebrae.
2 . HF & HV- Generator controlled by microcomputer, the exposure conditions are stable and accurate, and the rotation
angle is accurate, which meets the needs of clinical multi- position photography.
3 . Operation interface liquid crystal display, simple and convenient position information and exposure parameter setting,
x ray tube and the bucky are interconnected,easy to focus .
4. The tube capacity protection and fault self- diagnosis can be displayed in code form for convenient use and maintenance.

Parameter
Main
configuration
Technical Parameters
X ray tube 1.X-ray tube modelXD52-30.5/125KV/XD52-10.40/150KV
2.Focus:Double focus 1x1,2×2
3.The rated speed of the anode is 2800r/min

Multifunctiona
Radiology table
1.Table surface movement:electromagnetic lock pedal release
Vertical:±560m.Horizontal:±120mm
2.Fixed X-ray grid:Line:40L/cm,Grid Ratio:10:1,F.D:100cm.
Movement range:610mm
3.Radiography  specifications:5"x7",8"x10",10"x12",11"x14",12"x15",14"x14",
14*x 17
4.Table surface to film distance:75mm
5.Table height:700mm
6.Column movement:180 every 90 positioning,longitudinal stroke 1500mm.
7.Column movement:180 every 90 positioning,longitudinal stroke 1500mm
X ray collimator Max irradiation field:SID(FFD)=1000mm hours,no less than 430 mmx 430 mm
Min irradiation field:0×0 mm
nherent filter:1 mm·Al/75kVp
Additional filter:1 mm·Al and 2 mm·Al
Lead leaf control mode:manual
Working power:24V AC/DC,150 W(The lowest safe voltage)

HV-Generator
Power
Supply
Voltage:380V/220V±10%
Frequency:50HZ±1HZ
Resistance:≤0.3Ω
Radiography
Parameters
nverting Frequency:≥30kHZ
Power:≥50kW
Tube Current:16-500mA,Steps are adjustable
Tube Voltage:45-125KV,Stepping is 1KV
Exposure Time:0.01-6.3S,26 steps
Selection Mode:64 kinds of exposure conditions are stored,the
operator can choose them freely
APR storage capacity:2400 data

RELATED PRODUCT

×

Get in touch

Have Questions about Medical Equipment?

Our professional sales team are waiting for your consultation.

GET A QUOTE