50KW Floor-mounted X-ray
1.YJ-BW50 is a DR Floor-mounted Digital Radiography System.
2.High quality and efficient rage screen with human computer interaction design makes operation easy.
3.You need to step on the brake to move or stop the table floating in 4way,and the patient teals more secure when lying down.
4.The advanced technology of shock absorption and nonerection and the imported motors minimize the noise.
5.Power operated design automatic tracking one key in place, intelligent motion
6.The radiography table is made of cation bier material which has uniform testule attenuation is relatively small.
Product Brochure:DOWNLOAD
- Video
- Introduction
- Parameter
Video
Introduction
1.Standard AEC automatic exposure control makes exposure easier.
2.A fiat panel detetor with double-plate design is good for customers
3.Modular platfom design makes maintenance convenient.Selftest after power on.If there is any fault,the fault code will be displayed in time.
4.The control console with touch PAD can design exposureparameters during operation.
5.Auto-adaptive exposure system no need to manually selectthe exposure track,makes the operation simple.
Parameter
YJ-BW50 Parameter
Parameter | 20kw 200mA/50kw 500mA |
Intermittent mode | 100kV,200mA,20kW100kV,500mA,50kW |
Power Voltage | Three-phase five wires 380V±38V |
tube current | Radiography16mA~200mA Radiography16m |
Qutput Voltage | Radiography 40-125KVstep 1kV |
resistance powe | less than 0.50 |
Output power | 20kW 50kW |
Exposure Time | Radiography 0.0025s~6.4s adjustable |
Nominal Frequency | ≥30kHz |
Anode speed | 2800r/mi |
Anode heat capacity | 140KHU |
Focus Small focus | 1.0mm Large focus:2.0mm |
L*W*H of bed surface | 2100mm×825mmx650mm |
Horizontal moving range | ≥250mm |
Vertical moving range | ≥825mm |
grid density | ≥40 lines/cm |
grid ratig | 10:01 |
Focus Distance | 100cm |
Cassette size | 5"×7"8"×10"10"×12"11"×14"14"×17" |
Features
Detector |
1.Advanced dual detector design (wired and wireless),switching freely, meets the requirement of different hospitals.
2.The new battery pack has longer service lie and shorter charging time. The standby time is longer than 7 hours.
3.A large imaging area which is 17 x17”can meet the needs of muti.-scene clinical photography.
4..The direct growth technology of cesium iodide is used to obtain better images at the same tine of low dose.
|
Generator |
1.Compadt and high ftequengy generator 2.Leading internatioa high frequene inverter technology with inverter frequeney up to 400KHz 3.The highly accurate radlation dose output protects the paitients radiation safety wholeheartedly. 4.Uta-wide range milisecond level control.with AEC,wo-point,and three point esposure modes,meets dfferent users needs. |