Dr Mammography X-Ray Machine
1.YJ-DM156B is Digital Mmamography system all for Women's Health
2.Precise Diagnosis Solution for Mammography Screening!
3.Integrated Mechanical Parts Design.
Product Brochure:DOWNLOAD
- Video
- Introduction
- Parameter
Video
Introduction
1.Common part imaging with one-key position, high efficiency Safe up-and-down movement or rotation CC and MLO radiography
2.Super 315° wide angle C-arm design in industry, SID with large range movement mammography requirements of different body shapes can be satisfied
3.Dynamic information showed on LCD convenient for doctor observation.
4.C arm with iso centric rotation design, quick and convenient.
5.One-key position for common parts, easy and convenient. Foot switch to control compressor and C arm up-and-down movementoperation becomes high efficient. AEC automatic exposure control,save time, promote checking efficiency Smart compressor system,automatic release after exposing comfortable and safe
6.Tube with various configuration,Mo/Mo or W/Ag filter. No matter high ratio fat, or high ratio gland of requirements of Mammography radiography can be all satisfied
Parameter
Power supply | 5kW |
Output Voltage | 20-40kV |
Input Voltage | 220v |
Current | 10-200mA |
mAs Range | 10-500mAS |
Frequency | 50/60KHZ |
Work mode | Intermittent |
Power requirement | 180-264V AC |
Features
Large size flat panel detector | With 24cm x 30cm large size flat panel detector, radiography requirement of various sizes can be satisfied,whole mammary and axillary versus sentinel lymph node part can be displayed completely |
Fast imaging | High spatial resolution, fast imaging,tiny lesion can be seen clearly |
X-Ray Tube |
Focus: 0.1 / 0.3mm
Anode Heat Storage Capacity: 300kHU
Target Surface: RT-TZM Target Anode type: Rotating |
HF Generator |
Power Supply: 5kW
Output Voltage: 20 - 40kV Input Voltage: 220V Range of Current: 10-200mA Range of mAs: 10 - 120mAs (Small focus) Range of mAs: 10 - 500mAs (Large focus) Frequency: 50/60KHZ Work Mode: Intermittent Power Requirement: 180-264V AC |
Imaging System |
Detector Technology: a-Si Flat Panel Detector
Scintillator Material: CsI Detector Size: 240 x 300mm Static Pixel Matrix: 4096 x 3072pixels Pixel Size: 77μm Grayscale: 16 bit Preview Image: ≤ 5s
Spatial Resolution: 6 lp/mm AEC Function |
C-arm Stand |
FID: 1420 - 2020mm
Angle Range of Arm Rotation: -135° - +180° SID: 650mm Range of Arm Up and Down: 0—600mm One-click Function
Isocentric motion |
Grid |
Grid Density: 332.5 Line/Inch(±1)
Grid Ratio: 4 : 1 Focus: 645mm |