Dynamic FPD X-Ray Machine
1.YJ-PLD6000 had digital dynamic imaging system
2.Flexible and efficient multi-dimensional movement
3.Full satistaction in varieties of positions.
Product Brochure:DOWNLOAD
- Video
- Introduction
- Parameter
Video
Introduction
1.YJ-PLD6000 Registration:routine registration, emergency registration,adding agreement, adding item,clearing information,starting inspection;
2.Work list:list information,patient search to be examined,refresh to be examined list,delete examination,display column settings.Start in spection an demergency registration;
3.Check list:listinformation,checkedpatient display and search,delete image,image storage, discburning ,additem,display column setting,modify check information;
4.Patient's body type:thin adult,adult,fat adult;
5.Photography parameter setting:exposure mode,frame rate setting,kVp,Ma,MS, MAS,AEC,focus selection;
6.Perspective parameter setting:exposure mode,framera tesetting,kVp,Ma,ABS, time reset;
Parameter
YJ-PLD6000 Product Parameter
ltem | Content | Technical parameter |
Power Supply | Voltage | 380V±38V |
frequency | 50Hz±1Hz | |
capacity | ≥105kVA | |
internal resistance | ≤0.17Ω | |
High voltage generator (FSQ65RF) |
Maximum output power |
65.5kW |
Main inverter frequency |
500kHz,tolerance±20% | |
Radiography tube voltage |
40kV~150kV | |
Radiography tube current |
10mA~800mA regulation in steps | |
Radiography time | 1ms~10000ms regulation in steps | |
Radiography mAs | 0.1~1000 mAs | |
Fluoroscopy voltage | 40kV~125kV Continuously adjustable | |
Fluoroscopy current | 0.5mA~10mA(Continuously fluoroscopy 5mA~20mA(pulse fluoroscopy) |
|
Collimator (XSQ20) |
Equivalent tota filtration |
≥1mmAL |
beam limiter view light |
LED lamp beads,DC3.6V/5W | |
Visible light illumination and brightness |
Center average irradiation brightness: >100LUx |
|
Light and fielo exposure time |
5-45s,5s per step | |
X ray tube (E7252X) |
Nominal anode input power |
Big focus 75kW(180 Hz 0.1s Small focus 27kW(180 Hz0.1s) |
Anode heat capacity | 210KJ(300kHU) | |
Component heat capacity |
475kJ(667kHU/min) | |
Rotating anode speed |
9700rpm(180 Hz) | |
Tube focus | Big focus 1.2mm/small focus 0.6mm | |
Target angle | 12° | |
Diagnostic (ZDC20F) |
Table rotating range | +90°~0°~-25° |
Longitudina movement of point device |
1000mm,Tolerance±20 mm | |
Lateral movement range of table surface |
Not less than 220mm | |
SID | 1000mm~1800mm;Tolerance±20 mm | |
Rotating foot peda | 360°Infinite rotation(optional) | |
Filter grid | 498.5×499mm 230L/INCH 10:1100cm 498.5×499mm 103L/INCH 10:1180cm manual switching |
|
Dynamic flat panel detector (DRF-1717A |
Fffective area | 434mm(H)×434mm(V |
Prime matrix | 3072(H)×3072(V | |
Prime particle spacing |
139μm | |
Pulse fluoroscopy | 12fps/1408x1408 16fps/1024x1024 22fps/768x768 |
|
Continuous fluoroscopy |
13fps/1408x1408 20fps/1024x1024 30fps/768x768 |
|
Serial radiography | 3fps/3072X3072 | |
6fps/1536X1536 | ||
Point point | 3072X3072. | |
1536X1536 |
Features
1.Freely Floating:The table surface can be floated for as much as 220mm to save the trouble for patient movement.
2.Freely Column Movement:The detector can be moved in large range which helps the patients re-positioning.
Item | Model | Quantity | Remark |
Console | KZT70A | 1 | PLD |
High voltage generator | FSQ65RF | 1 | PLD |
X ray tube | E7252X | 1 | Cano |
Collimator | XSQ20 | 1 | PLD |
Diagnostic table | ZDC20F | 1 | PLD |
Grid | 1.0/1.8m | 2 | JPI |
Dynamic flat panel detector |
DRF-1717A | 1 | PLD |
mage acquisition workstation |
DRA80 | 1 | PLD |
Accessory | PLD6000 | 1 | PLD |