FEEDING PUMP
Unique rotary number setter, easy and quick parameter setting
Dual-MPU design, more secure system operation
Comprehensive audible and visual alarm function, adjustable volume and 360 visible
Swift priming and flushing function available
Product Brochure:DOWNLOAD
- Introduction
- Parameter
Introduction
▲Memory and recall function for last setting
▲Ultrasonic bubble detection technology
▲Instant detection of dynamic pressure, facilitating clinical monitoring & prediction, and lowering occlusion risks
▲Emergency power supply with removable battery for swift transportation and maintenance
▲Reserved port for optional exclusive thermostat
▲Embedded handle for better space-efficiency
▲USB port forsystem upgrade and data storage
▲Optional exclusive/universal feeding sets, higher feeding accuracy and lower occlusion risks
Parameter
Technical Specifications
|
|
Infusion rate (ml/h)
|
1~400 ml/hr in 1 ml increments
|
Mean flow velocity accuracy
|
±10% of selected flow rate
|
Dosage limit(ml)
|
0-9999 in 1 ml increment
|
Meanvolume accuracy
|
±10%
|
Loading speed andmeanaccuracy(ml/h)
|
1000±10%
|
Cleaning speed and mean speed accuracy(ml/h)
|
1000±10%
|
Max volume flush and mean speed accuracy(ml)
|
40±10%
|
Mx feeding pump pressure
|
≥0.1 MPa
|
Occlusion alarm level (pressure)
|
50KPa±10KPa
|
The longest occlusion triggering time of this device at minimum flow rate
|
43min
|
The shortest occlusion triggering time of this device at intermediate flow rate
|
85s
|
Medium speed running the pills from blocking the alarm threshold
|
0.79ml
|
Recoverable Alarm
|
1min50s-2min
|
Pause overtime alarm time
|
1min50s-2min
|
Heating temperature
|
Infusion flow rate ≥20ml / h, 375px distance away from the heater outlet at 25-38 ºC
|
Use of infusion set
|
See recommended infusion sets list
|
Air-in-line sensitivity
|
Detestability of single size of air bubble ≥50uL
|
Alarm
|
Occlusion alarm, Over heatedalarm, battery depleted alarm
|
Alarms
|
Air in line,Prime, Flush, low power, failurecodes(ERxx), pause overtime, powerstate, infusion mode, work state, heaterstate.
|
Noise
|
Measured at the highest flow rate on wooden table, the volume is lower than 50 dB at a distance of 1 meter
|
Power
|
Ac: 100V-240V 50 Hz /60Hz
|
Built-in battery
|
A fully charged internal DC11.1V battery can continuously run the pump for approximately 5 hours on intermediate rate
|
Power consumption
|
≤40VA
|
Power output
|
≤20VA
|
The rated output voltage
|
15V
|
Weight
|
2.0kg
|
Heater
|
W-E01 ,cable length is 1.5m,Shield
|
Essential performance
|
This product is suitable for patients with enteral nutrition infusion, the host cancontrol the infusion rate. With
alarmfunction,with bubble detection piping and piping blockage detection. |
Classification
|
type BF,class ΙΙ continuous volumetric feeding pump with internal battery;IPX1 (sealed drip-proof device)
|
Dimensions
|
155mm(L)×170mm(W)×180mm(H)
|
Accessories
|
1 user manual, 1 power cable, 1 heater(EA312/313 models only)
|