Color doppler ultrasound scanner

domum /  Products  /  ultrasound scanner  /  Color doppler ultrasound scanner

Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60
Cardiac ultrasound Machina YJ-T60

Cardiac ultrasound Machina YJ-T60

1. Elastography

2. TDI 

3. Anatomic M Modus 

4. Sanguinis fluxus M (CM) Modus 

5. Auto IMT 

6. Panoramic Imaging 

7. Trapezoidalis , Declinatio imaginis 

8. Spatium imaginatio composita 

9D 

10. Free manus 3D 

11. THI & FHI 

12. CW 

13. punctura amplificationem 

14. 21.5 inch LED Screen+13.3inch Touch screen

Dives Probes:
* Convexum specillum ; 
* tran-vaginale specillum ;
* Specillum linearium ;
* Specillum Micro-convexum; 
* Cardiac specillum ;
* 4D Codices Probe

Productum Brochure:Download

  • Video
  • Introduction
  • Parameter
Video

Introduction

YJ-T60 Trolley Color Doppler ultrasound apparatus 2D ECHO

Latum range de applications

Systema applicationis systemica praecipue adhibetur in diagnosi et inquisitione abdominis, OB&GYN , Cardiac, Urinariae, Particulae parvae, Superficialis, Vascularis, Pediatricae (neonatalis), Emergency, Examen Physica et aliae examinis et diagnosis aspectus.

Applicatio capacitatum cardiovascularium, peripheralium vasorum sanguinis, obstetricarum et gynaecologiae, abdominis, cordis foetus, fibras superficiales et organa parva, interventus intraluminalis et punctura ultrasonans cum muneribus 4D analysi validis.
Core prudentia subtilis perceptio super clear 

Parameter
1: Summarium praecipuarum specificationum et systema cart type color doppler ultrasound
1.1 Trolley typus omnes digitalis color Doppler ultrasonic mainframe
1.2 Ultrasonic exercitum operating ratio: Fenestra operating ratio
1.3 Applications:
Abdomen, obstetrica, gynaecologia, cor, systema urinarium, organa parva, superficialia, vasa sanguinis, pediatrica, fœtus, musculoskeletales.
1.4 Probes:
Specillum convexum, Specillum Tran-vaginum, Specillum Linearium, Specillum Micro-convexum, Specillum Cardiac, 4D Volume
averso specillo diducendum
1.5 Applicationes et famae:
Abdominis, OB, GYN, Cardiac, Urinariae, Partes parvae, Superficiales, Vasculares, Pediatrics, Mensurae programmatum programmatum, nuntia programmata programmata, administratio fasciculorum programmatum, etc.
1.6 arteriae carotidis intima-media crassitudine (IMT)
1.7 Involucrum spectris automatic measurement
1.8 Plena digitalis transmissio et receptio trabi synthesizer
1.9 Color Doppler imaginatio (C)
1.10 Pulsus Doppler Imaging (PW)
1.12 Cohaeret Contra imaginatio (CCI)
1.12 Continua undam Doppler imaginatio (CW)
1.13 B/C/D
1.14 Virtus Doppler imaginatio (PDI)
1.15 Virtus directa Doppler imaginatio (DPDI)
1.16 M modus imaginandi
1.17 Anatomie M modus imaginandi 
1.18 Color Doppler M modus imaginatio
1.19 Elastographia 
1.20 TEXTUS Doppler imaginatio (TDI)
1.21 Conatus rate imaginatio (SRI)
1.22 TEXTUS harmonicae imaginatio (THI)
1.23 Fusion harmonica imaginatio (FHI)
1.24 Speckle Reducere imaginatio (SRI)
1.25 Panoramica imaginatio 
1.26 Declinatio imaginatio
1.27 Trapezoidalis imaginatio
1.28 Adaptiva velocitas ipsum
1.29 Free manus 3D
1.30 Verus tempus 3D imaginatio (3D/4D)
1.31 DICOM3.0
1.32 Monitor: ≥21.5 inch, alta definitio ultrasonica ostentationis
1.33 ≥13.3 inch tactus screen
1.34 Clipboard physica: nisi imaginem in parte sinistra veli, quae directe servari vel deleri potest.
1.35 Systema munus habet in upgrade-macula
1.36 Praesuppositio: pro diversis viscerum inspectione, conditiones inspectionis optimae imaginis, et operationis commensurationem reducens, et communitatem externam compositionis et compositionis constitutionem communiter adhibitam.
1.37 Probe interface: 4
1.38 Lingua: ZH/EN/VI/DE/FR/ES/RU/AR/PT/IN
1.39 Profundum:≥410mm;
1.40 Fundo imaginatio
2: Probes
2.1 Convexis probe Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,
Harmonica Frequentia:
4.0MHz/4.6MHz/5.0MHz
2.2      
Specillum linearium
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz,
Harmonica Frequentia:
8.0MHz/9.2MHz/10.0MHz
2.3 Trans-vaginal specillum Fundamental Frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz,
Harmonica Frequentia:
6.0MHz/7.0MHz/8.0MHz
2.4 Micro-convexum specillum Fundamental Frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz,
Harmonica Frequentia:
6.0MHz/7.0MHz/8.0MHz
2.5 Cardiac specillum adultum Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz,
Harmonica Frequentia:
3.4MHz/3.8MHz/4.2MHz
2.6 cardiacus specillum pediatric Fundamental Frequency:3.0MHz/ 3.5MHz/ 4.0MHz/ 5.0MHz/ 5.4MHz/6.0MHz/7.0MHz/8.0MHz
Harmonica Frequentia:
6.0MHz
2.7      
4D Codices probe
Fundamental Frequency:
2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz,
Harmonica Frequentia:
4.0MHz/5.0MHz/6.0MHz
3: 2D modus imaginandi
3.1 Lucrum: 0-100, Gradus II adjustable
3.2 TGC VIII segmentum adjustable
3.3 Maximum punctum focus: ≥7, quae per totum processum moveri potest.
3.4 Speckle reductionem: 0-5,5 level
3.5 Spatium Synthesis: 0-2,2 campus (probus lineus: 3 planities, cardiac specillum: 0)
3.6 Dynamic:30-180,35 level, step 5 adjustable
3.7 Linea densitatis: humilis, media, alta, 3 level
3.8 Artus reciproci: 0-4,4 level
3.9 Sonitus reductionis: 0-5,5 level
3.10 Ora Enhancement: 0-5,5 campester
3.11 Sana potentia: 2-10, 9 level
3.12 Scala grisea:0-67, 67
3.13 Color falsus: 0-67,67 level
3.14 Image style:Molle-Comparison,2 level
  Tegumentum reale tempus habet vocis ostentationem, explorationem frequentiae, dynamicam range, pseudo-colorem, scalam griseam et alios 11 parametris adaptari possunt.
4: Color Doppler imaginandi modus
4.1 Sanguinis lucrum: 0-100, Gradus 2
4.2 Parameter ostentus: Velocitas, Variatio
4.3 B cohibere (B/W cohibere): 0-7, 7 level
4.4 Celeritas per:0-8, 8 level
4.5 Sampling number: 6-24, 7 level
4.6 Sanguis fluxus malle: 0-8, 8 level
4.7 Filtering: 1-6, 6
4.8 Sana potentia: 2-6, 4 level
4.9 Reductio sonitus: 0-4, 4 level
4.10 Lenis curatio: 0-4, 4 level
4.11 Artus reciproci: 0-6, 6 level
4.12 Chromatographia (Sanguinis graphi): 0-37, 37 level
4.13 Linea densitatis: Minimum-Medium High, 3 level
4.14 Frequentia: IV gradu adjustable
4.15 Velocitas: Minimum 0.4K, Maximum 40.5K
Convexis probe:0.4K-4.3K-38.5K
Probabile lineari: 0.4K-14.7K-39.0K
Specillum trans-vaginale: 0.4K-7.8K-39.7K
Volumen probe:0.4K-4.2K-34.8K
Micro-convexum probe:0.4K-10.3K-40.5K
cardiacum probe:0.4K-7.8K-39.7K
  PS: Frequentia explorationis mutationes et frequentia valorem mutationes
  PS: Frame rate mutationes cum velocitate
5: Pulse fluctus Doppler(PW)
1 Lucrum: 0-100, Gradus 2
5.2 Involucrum spectrum functionis: involucrum spectri temporis reale automatic, involucrum spectri manualis, et alii modi. Systema automatice analyses variasque notitias ostendit ut PSV, EDV, RI, PI, S/D, ACC, HR et alia huiusmodi. Potest excitare vel prope
5.3 Sample volumen:0.5mm~30mm
5.4 Sanguis angelus: -75-75 gradus, Gradus 5
5.5 Color falsus: 0-67, 67
5.6 Dynamic range:20-40, 4 level
5.7 Filtrum: 0-9, 9 level
5.8 Lenis curatio: 1-4, 4 level
5.9 Sana potentia: 2-5, 4 level
5.10 Volume: 0-100, 10 level, Gradus 10
5.11 Audio eliquare:0-4, 4 level
5.12 Basi linea: -1.0~1.0,
5.13 Grey map:0-67, 67 level
5.14 Scan velocitas: 100-500, 6 level
5.15 PRF:Minimum 0.5K,Maximum 87.5K
Convexis probe:0.5K-4.3K-63.3K
Probabile lineari: 0.5K-14.5K-78.4K
Specillum trans-vaginale: 0.5K-8.1K-78.4K
Volumen probe:0.5K-4.2K-53.8K
Micro-convexum probe:0.5K-10.3K-81.1K
cardiacum probe:0.5K-4.3K-87.5K
5.16 Frequentia: gradu IV
  PS: Frequentia explorationis mutationes et mutationes valoris PRF
  PS: Frequentia explorationis mutationes et frequentia valorem mutationes
6: Continuus unda Doppler(C.)
6.1 Support probe: Cardiac probe
6.2 De revolutionibus B modus parametri est switchable
6.3 Lucrum: 0-100, Gradus 2
6.4 Sampling linea positio adjustable
6.5 PRF:0.9K~36.1K
6.6 Baseline: -1.0~1.0
6.7 Sanguis angelus: -75~75 gradus
6.8 Grey map:0-67
6.9 Scan velocitatis: 100-300
6.10 Color falsus: 0-67
6.11 Dynamic range:20-40
6.12 Filtering: 0-9,9 level
6.13 Lenis curatio: 1-4
6.14 Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable
6.15 Sana potentia: 2-5
6.16 Volume: 0-100
6.17 Audio Filtering: 0-4
7; M imaginatio anatomica
7.1 Support specillum: Specillum convexum, specillum linearium, specillum cardiac
7.2 De revolutionibus B modus parametri est switchable
7.3 Lucrum: 0-100, Gradus 2
7.4 M Sampling linea angelus adjustable
7.5 M Sampling linea longitudo est Novifacta
7.6 Sampling linea: 3, Proponendum vel occultum
8; Et effundatur sanguis M modus (MC)
8.1 De revolutionibus B modus parametri est switchable
8.2 Lucrum: 0-100, Step2
8.3 MC Sampling linea angelus adjustable
8.4 MC Sampling linea longitudo adjustable
8.5 Frequentia: gradu IV
8.6 Sampling numerus: 6-24
8.7 Celeritas per:0-8, 8 level
8.8 Scan velocitatis: 150-500
8.9 Artus reciproci: 0-6, 6 level
8.10 Filtering: 1-6,6 level
8.11 Sanguis fluxus malle: 0-8,8 level
8.12 Lenis curatio: 0-4,4 campester
8.13 Map:0-37, 37 level
9; Elastographia
9.1 De revolutionibus B modus parametri est switchable
9.2 Lucrum: 0-100, Gradus 2
9.3 B/E, Double real-time display on the same screen
9.4 Specillum obsessio curva ostentationem: Sursum / Est
9.5 Pressura indicator talea ostensionem
9.6 Frequentia: 8-9 gradu, Novifacta, secundum specillum ostentationem
9.7 Reductio sonitus: 0-2, 2 level
9.8 Artus reciproci: 0-3, 3 level
9.9 Comparatio: 0-13, 13 level
9.10 Color falsus: 0-3, 3
9.11 Nolite sustinere cardiac specillum
10; TEXTUS Doppler imaginatio (TDI)
10.1 Support specillum: cardiac probe
10.2 De revolutionibus B modus parametri est switchable
10.3 Lucrum: 0-100, gradus 2
10.4 ROI area Novifacta
10.5 Sampling numerus: 6-24
10.6 Velocitas: 0.4K-8.0K
10.7 Artus reciproci: 0-6,6 level
10.8 TEXTUS malle: 0-7, 7 level
10.9 Frequentia: 2.0MHz/2.3MHz/2.5MHz/3.0MHz
10.10 Suscipe color conversionis
11; Contendunt rate imaginatio
11.1 Support specillum: cardiac specillum
11.2 De revolutionibus B modus parametri est switchable
11.3 ROI area Novifacta
11.4 Lucrum: 0-100, Gradus 2
11.5 Sampling numerus: 6-24,6 level
11.6 Axialis mediocris: 1-4, 4 level
11.7 Velocitas: 0.4K-8K
11.8 Artus reciproci: 0-6, 6 level
11.9 TEXTUS ipsum: 0-7,7 campester
12; Panoramica imaginatio
12.1 Support specillo lineari specillo
12.2 Speckle reduction: 0-5, 5 level
13; Declinatio imaginatio
13.1 Support specillo lineari specillo
13.2 De revolutionibus B modus parametri est switchable
13.3 Declinatio angelus: VIII gradu
13.4 Speckle reduction: 0-5, 5 level
13.5 Dynamic rate: 30-180, Gradus 5
13.6 Linea densitatis: humilis media alta, gradu III
13.7 Frame Correlation:0-4 level
13.8 Color falsus: 0-67, 67
13.9 Image style:Molle-Comparison,2 level
13.10 Reductio sonitus: 0-5, 5 level
13.11 Ora Enhancement: 0-5,5 campester
13.12 Sana potentia: 2-10,8 level
13.13 Grey map:0-67,67 level
14; Trapezoidalis imaginatio
14.1 Specillum firmamentum linearibus probe
14.2 De revolutionibus B modus parametri est switchable
14.3 Declinatio angelus: VIII gradu
14.4 Speckle reduction: 0-5, 5 level
14.5 Dynamic rate: 30-180, Gradus 5
14.6 Linea densitatis: humilis media alta, gradu III
14.7 Frame Correlation:0-4 level
14.8 Color falsus: 0-67, 67
14.9 Image style:Molle-Comparison,2 level
14.10 Reductio sonitus: 0-5, 5 level
14.11 Ora Enhancement: 0-5,5 campester
14.12 Sana potentia: 2-10,8 level
14.13 Grey map:0-67, 67 level
14.14 Spatium Synthesis:0-2, 2 level
15 Freehand 3D imaginatio
15.1 Support specillo: specillo convexo, specillo lineari
15.2 Exemplar ostende: 4 imagines
15.3 Imago gyrationis X/Y/Z Axis
15.4 Multi- scalpere Visibilitas
16 Real-time 4D imaginatio
16.1 Support specillum: 4D volumen probe
16.2 De revolutionibus B modus parametri est switchable
16.3 Lucrum: 0-100, Gradus 2
16.4 Exemplar exhibe: una imago, duae imagines, quattuor imagines
16.5 Imago gyrationis: X/Y/Z Axis
16.6 Multi- scalpere Visibilitas
16.7 Lux & umbra inversionem
16.8 Smooth:0-4, 4 level
16.9 Limen planum: 0-129, Gradus 3
16.10 Perspicuus: 1-509, Gradus 10
16.11 Redde type:4 species, superficies, maximum, minimum, prospective
17: Panoromic Imaging 
17.1 Lucrum: 0-100, Gradus 2
17.2 TGC VIII segmentum adjustable
17.3 Maximum punctum focus: ≥7, quae per totum processum moveri potest.
17.4 Speckle reductionem: 0-5,5 level
17.5 Spatium Compone: 0-2,2 gradu (linearibus probe: 3 gradu, noli cardiac probe)
17.6 Dynamic range:30-180,35 level, Gradus 5
17.7 Linea densitatis: Minimum, Medium, Maximum, 3 planum
17.8 Artus reciproci: 0-4,4 level
17.9 Sonitus reductionis: 0-5,5 level
17.10 Ora amplificationem: 0-5,5 gradu
17.11 Sana potentia: 2-10, 9 level
17.12 Grey map:0-67, 67 level
17.13 Color falsus: 0-67,67 level
17.14 Image style:Molle-Comparison,2 level
17.15 Protractum gradum: Maximum LXXII gradu
Convexis probe: IX level
Trans-vaginal probe:72 level
Micro-convexum probe: XXIX planum
Cardiac probe:40 level
4D Volume probe:17 level
  PS:Tegumentum reale tempus habet vocis ostentationem, explorationem frequentiae, dynamicam range, pseudo-colorem, scalam griseam et alios 11 parametris accommodari possunt.
  PS: Cum specillum extensionis ad maximam pervenit, spatium summatim perstringitur 0 .
18: Munus mensurae et analysis:
18.1 Mensura generalis: Distantia, area, ellipsis, linea crucis, angulus, distantia ratio, volubilis, Volume (ellipsis), area ratio, diametri, angulus articularis.
18.2 Cardiac: spectrum automaticum involucrum, LV, arteria principalis pulmonalis, RVEDd, RVEDs, LVM, LAV, HR, MVF, AO, AR, LVOT, TVF, valvae pulmonis, vena pulmonalis, RV, Doppler foetus cor sanum, LVET, LVM, LVMI, AV
18.3 vascularis: carotidis intima (IMT), longitudo stenosis ratio, area stenosis ratio, IMT (murus posterior), IMT (murus anterior)
18.4 OB:Fetalis usitatum, AFI, TW, GS, CRl,OFD, HL, ulna, NT, Fibula, Nbonel, Radial, Tibia
18.5 GYN:uterus,cervix,corpus uteri/cervix uteri, sinistra ovaria, vena ovaria dextra, folliculus dominans, crassitudo intima
18.6 Urologia: prostate, residua urina, renibus sinistra, renibus, renibus, sinistra suprarenalis, ius suprarenalis, sinistra testis, ius testis, vesicula seminalis sinistra, vesicula seminis ius
18.7 Abdomen: hepar, CHD, venae partis pars diametri, cholecystus, pancreas, splenis, diametro internus aortae abdominis, renibus.
18.8 Particulae parvae: Thyroideum
18.9 Software sarcina: Mensurae sarcina, Software sarcina, medical monumenta administratione software sarcina
19: Graphica et textus systematis procuratio
19.1 Hospes constructum in 2 rigidum (SSD 128GB+ HDD 1TB), Committitur ieiunium et stabile, RAM: 8GB
19.2 Movie playback: ≥1200 tabulae
19.3 Internum fasciculi delineatio notitiarum ratio: patiens numerum, nomen, numerum, numerum ceptum notare potest, diem ceptum et cetera, et investigari et administrari potest numerando, annotando numerum, nomen et cetera.
19.4 Genus fama est XVI "
19.5 One key fast report graphic and text management
20: Interface
20.1 USB interface: *4
20.2 HDMI interface: *1
20.3 RJ-45 interface: *1
20.4 Grounding filum interface: * 1
20.5 Fuse: *2
20.6 DVD RW: *1
 21: configuration
21.1 Trolley type plenus digital color Doppler ultrasound diagnostica system
21.2 Probe: specillum convexum (vexillum), specillum linearis (libitum), specillum trans-vaginale (libitum), specillum cardiacum (libitum), 4D volumen specillum (libitum)
21.3 ≥13 velox adjusting spherae
22: Technologia, post-venditio muneris et aliis requisitis
22.1 Post acceptationem, warantia per duos annos liberum est (Provide manufacturer warranty libellum)
22.2 Fabricator certificationem ISO13485 et EU CE certificationem habet.