1. YJ-PLD6000 habuit systema imaginis digitalis dynamicae.

2. Motus multiformis et efficax in pluribus dimensionibus.

3. Plena satisfactio in variis positionibus.

Brochure Producti: Descarga

  • Video
  • Introductio
  • Parametrum
Video

Introductio

1. YJ-PLD6000 Registratio: registratio usualis, registratio urgentis, additio conventione, additio item, delenda informatio, initium inspectionis;

2. Index laboris: informatio indicis, quaerere patientem inspecturum, referare indicem inspecturi, delere examinationem, columnae indicis dispositio. Initium inspectionis et registratio urgentis;

3. Index inspectionis: informatio indicis, ostendere et quaerere inspectos patients, delere imaginem, conservare imaginem, discum cremare, addere item, dispositio columnae indicis, mutare informationem inspectionis;

4. Corporis typus patientis: exilis adultus, adultus, crassus adultus;

5. Configuratio parametri photographici: modus expositionis, configuratio velocitatis imaginum, kVp, Ma, MS, MAS, AEC, selectio focalem;

6. Configuratio parametri perspectivae: modus expositionis, configuratio velocitatis imaginum, kVp, Ma, ABS, reset temporis;

Parametrum

Parametri Producti YJ-PLD6000

ltem Contentum Parameter Technicus
Potentiae copia Voltage 380V±38V
frequency 50Hz±1Hz
capacitas ≥105kVA
resistentia Interna ≤0.17Ω
Alta voltage
generator
(FSQ65RF)
Maximum output

potentia
65.5kW
Principalis inversor
frequency
500kHz, tollerantia±20%
Tubus radiographicus
voltage
40kV~150kV
Tubus radiographicus

current
regulatio 10mA~800mA gradatim
Tempus radiographiae regulatio 1ms~10000ms gradatim
MAs radiographiae 0.1~1000 mAs
Tensio fluoroscopica 40kV~125kV Ajustabilis continuus
Fluxus fluoroscopici 0.5mA~10mA (Fluoroscopia continua)

5mA~20mA (Fluoroscopia impulsa)
Collimator
(XSQ20)
Aequivalent totalis

filtratio
≥1mmAL
visio limitatoris radii
lux
Granula lucernae LED, DC3.6V/5W
Lumina vizibila
illustratio et
claritas
Centrum medium splendor irradiationis:
>100LUx
Lumen et fielo

tempus expositionis
5-45s, 5s per gradus
Tubus X radii

(E7252X)
Anoda nominalis
potentia Input
Magnus focus 75kW(180 Hz 0.1s

Parvus focus 27kW(180 Hz0.1s)
Capacitas Caloris Anodis 210KJ(300kHU)
Component caloris
capacitas
475kJ(667kHU\/min)
Anulus rotans
celeritas
9700rpm(180 Hz)
Foculus tubi Magnus focus 1.2mm/parus focus 0.6mm
Angulus scopi 12°
Diagnostic
(ZDC20F)
Orbis rotationis tabulae +90°~0°~-25°
Longitudina
motus puncti
machina
1000mm, Tolerantia±20 mm
Motus lateralis
rangus tabulae
superficies
Non minus quam 220mm
SID 1000mm~1800mm; Tolerantia ±20 mm
Peda rota 360°Rotatio infinita (facultativa)
Cratis filtrum 498.5×499mm 230L/INCH 10:1100cm
498.5×499mm 103L/INCH 10:1180cm
commutatio manualis
Planum dynamicum
detector pannello
(DRF-1717A
Area efficiens 434mm(H)×434mm(V
Matrice principalis 3072(H)×3072(V
Particula prima
interstitium
139μm
Fluoroscopia Impulsuum 12im/s/1408x1408
16im/s/1024x1024
22im/s/768x768
Continuus
fluoroscopia
13fps/1408x1408
20fps/1024x1024
30fps/768x768
Serialis radiographia 3fps/3072X3072
6fps/1536X1536
Punctum punctum 3072X3072.
1536X1536

Caracteres

1. Libere Fluitans: Superficies tabulae potest fluitare usque ad 220mm, ut patientis motus incommodum evitetur.

2. Libera Movendi Columnae: Detector moveri potest in amplitudine magna, quod adiuvat repositionem patientium.

3. Libera Rotatio: Flexibilis rotatio tabulae facit radiographiam et angiographiam obliquis angulis necessariam.
Res Exemplum Quantitas Animadverte
Console KZT70A 1 PLD
Generator altus voltagii FSQ65RF 1 PLD
Tubus X radii E7252X 1 Canna
Collimator XSQ20 1 PLD
Tabula diagnosticus ZDC20F 1 PLD
Eget 1.0\/1.8m 2 JPI
Tabula plana dynamica
detector
DRF-1717A 1 PLD
imago acquisitionis
officina
DRA80 1 PLD
Accessio PLD6000 1 PLD