1.YJ-MO30 apparatus mammogram peculiaris, humilis dosis X-radii ars ad imaginem pectoris adhibita est, deprehendens et diagnoses quasvis massas abnormes vel missas in pectore texti.
2. Est unum ex primis instrumentis ad cancrum mammae primae cognitionis.
3. Cum prima identitate, cancer mammae in primo stadio curari potest, et recuperatio verisimilius est.
Productum Brochure:Download
- Video
- Introduction
- Parameter
Video
Introduction
Features:
1. Unique soli- tate alta frequentia alta voltage generans omnia adoptat. Haec ars patentes in USA obtinuit.
2. Tutissimum est mammographiae alta intentione. Est constructum-in X-radii ignitionis coil in machina exercitus, alta vis lineae vis minus quam 25cm.
3. Electrica Isocentrica C-brachium rotatum cum singulari automatic ad centrum functionis reduxit.
4. Libitum tertiae generationis euismod importatum movens.
5. Auto/semi-auto/manual, tres modi expositionis.
6. Optional image output device: digital film printer.
7. A summa 3 frusta magnae magnitudinis versicolores LCD tegumentum propono, operatio mensa 8 inch LCD velum clavis tactus est.
8. Comfortable Compressione
Cum aliquis gradus pressionis ad radiographiam requiratur, sinit vos pressionem convenientem pressi (usque ad maximum 20kg) et instructum systemate molliti-tactis MICOM Control, quod ad extenuandum incommodum examinandi cum pressione destinatur. complector.
TEXTUS Cogo: Manuale et Motorised (Max 20kg)
Cogo Force et Crassitudo Data Display
Compresce Micro control scriptor
Automatic Release
9 intelligentes Lorem Patefacio Imperium (AEC)
Cum exposita Automatica Dispositione Imperium, imagines producere potest cum certa intensione apta et cinematographica, velum, vel methodum radiographiae.
Praeterea valde auget commoditatem radiographiae, functionem plenariam AEC implicando, quae possit uti auto- kV.
Typus: Firmus-rei publicae Detector
Microprocessor Imperium
AEC Modus: Full AEC (Auto kv)
Semi AEC (kV Select)
Manual (kV, mAs Select)
Density Temperatio: XVI gradus densitas
10. X-ray Tube
Exemplar: Sina Hangzhou LR01
Focus Macula Location: Dual Focus 0.2 / 0.4mm
Scopum Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Summus celeritate anode coegi: 2800 / 1000rpm
Scopum angulus 12°/12°
Anode Calor Storage: 100KJ(150KHU)
Anode Refrigerationem: Aeris refrigerationem
Filtration: Mo(0.03mm) Al(0.5mm)
Parameter
ltem | Parametus | Attende |
X-ray Generator | Generator Type: High Frequency Inverter 80kHz Radiographica Rating: Large Focal Point 20-35kV/10-510mAs Focale parvum 20-35kV/10-100mAs Potentia Rating: 6kVA |
Sui evoluta et orbis terrarum all- solidum-status summus frequency altum voltage x-ray generato |
X-ray Tube | Focus Spot Size: Dual Focus 0.1/0.3mm Target Material: Molybdenum (Mo) Port Material: Beryllium (Be) Summus celeritate anode coegi: 2800710000rpm Target angulus: 10°716° Anode Calor Storage: 300kHU Anode Refrigerant: Aeris refrigerationem Filtration:Mo(0.03mm)Al(0.5mm) |
Exemplar: IAE C339V |
Radiographica stabit |
C-ARM Centrum electrici rotationis C-brachii, munus reditus automatice per unum clavem Rotationes Degree:+90°~-90° Automatice dimisit post nuditate pressura occasus display.Compression flexibile sine velocitate Max.pressure:200N Max.travel:150mm SID:650mm |
|
Cassette Image Receptor |
Bucky Fabrica: 18x24cm Bucky coegi mechanism Eget Ratio:5:1,30 Line/cm |
24x30cm ad optiona |
alii | recta intentione 220V ac±10%25A,Single phase |
110V ad optiona |