Medical Infusion Pump
3.5-inch LCD screen, Multiple languages Customization
Wide range of flow rate: 0.01 -2000ml/h
Comprehensive audible and visual alarm function, adjustable volume, visible from 360°
Ultrasonic bubble detection technology
Change flow rate without stopping the current task
Optional: Thermostat function , Drop sensor
Product Brochure:DOWNLOAD
- Introduction
- Parameter
Introduction
Easy calibration of near completion, volume and infusion sets etc.,for more friendly use.
Drug library contains more than 50 drug names, and can be updated & programmed.
Three infusion modes including Rate, Time,Body-weight.
DPS(Dynamic pressure System)
Powerfull alarm system with 360 visual light signs, easy for clinical identification.
Double CPU to ensure system security.
Manual & automatic bolus, can be programmed according to clinical use.
Automatic anti-bolus to decrease unexpected clinical risk.
Top accuracy in the world: Flow rate increments by 0.01ml/h, +-3%(SC115)
Parameter
Model |
SC113 |
Infusion principle |
Fingertip peristaltic pump |
Infusion mode |
Time Mode, Rate mode, Body Weight Mode, mg/kg/min,mg/kg/h,ug/kg/min,ug/kg/h,etc |
Drug Name Display |
More than 50, Can be updated according to customer requirements or clinical use |
Accuracy |
+-5% |
Time Preset |
0-99h and 59min |
Volume range |
0.01-9999.99ml |
infusion rate range |
0.01-1800ml/h(1000-1800ml/h by A.C.) |
Infusion ratge step by |
Increments at 0.01ml/h |
Volume infused |
0-9999.99ml |
Total volume infused |
0-9999.99ml |
Purge/Bolus rate |
1-1800ml/h, can be programmed by user, default rate 800ml/h (1000-1800ml/h by A.C.) |
Bubble sensitivity |
Detestability of air bubble more than 50ul |
Occusion pressure |
High: 100kpa+-30kpa, Middle: 60Kpa+-25Kpa Low: 40kpa+-20kpa |
Audible & visible alarms |
Air in line, Occlusion, Door open, VTBI completion, Low battery, Drop error, Pause overtime, Master CPU malfunction, Monitoring CPU malfunction, Air betect module error, Pressure detect module error, Motor malfunction, Battery exhausted, I.V.Set Error(Sc115), Heating Error(SC113), A.C connection, A.C disconnection |
KVO |
1ml/h-5ml/h,defaut rate 1ml/h,can be programmed by user |
Power & battery |
30VA 55VA(SC113) AC:100V-240V 50HZ/60HZ DC:11.1V Lithium battery support from 7 to 10hours |
Calssification |
Class II, type CF, IPX4 |
Optional Function |
Temperature: +-5C--+40degree C, Relative Humidity: 20%-90% Atmospheric pressure 70Kpa-106Kpa |
Dimensions |
Event log with at least 2000 history records;DC input |
|
140x260x110mm |
Weight |
2.5kg |