Portable defibrillator machine AED
1.Light weighted defibrillator
2.Multi-parameter Patient Monitor Manual defibrillation
3.Automated External Defibrillalator(AED) pacer (option)
4.Screen:8 inch High-resolution display
5.Sweep Speed: 25mm/sec
6.5 Languages available:English、Russian、Spanish、Chinese、Turkish
Product Brochure:DOWNLOAD
- Video
- Introduction
- Parameter
Video
Introduction
YJ-D9000 is a compact, durable, light weighted defibrillator which integrated monitoring, manual defibrillation, AED and pacer (option).
It is a professional biphasic defibrillator-monitor suitable for hospitals and clinics
Parameter
Display
|
|
· Screen Type: High-resolution display
|
SpO2 Module (Options):
|
· Screen Size: 7 inches (17.7 cm) diagonally
|
· Measurement Range: 30~100%, ±2% between 80%~90%, others ±5%
|
· Sweep Speed: 25mm/sec
|
· Alarm Range: User set high limit and low limit.
|
· Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED
|
· Alarm Accuracy: ±10% within setting values.
|
· Functions and Prompts Alarm Selection and Limits, Delivered Energy.
|
· Alarm time Accuracy: less than 12 sec.
|
Defibrillator
|
EtCO2 (Options)
|
· Waveform: Biphasic
|
NIBP (Options)
|
· Charge Time: Less than 7 seconds with a new fully charged battery.
|
Recorder
|
· Energy Display: Monitor display indicates both selected and delivered energy.
|
· Paper: 50mm thermal.
|
· Charge Prompt Type: Voice and visual prompts.
|
· Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
|
· Electrode Impedance Measurement Range: 0- 250 ohms.
|
· Printing Method: High-resolution, thermal print head.
|
ECG Monitoring
|
· Print-out Modes: Manual or automatic, user- configurable.
|
· Patient Connection: 3-lead ECG cable, or 5- lead ECG cable, paddles.
|
· On/Off Control: Front panel and paddle.
|
· Lead Selection: Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V.
|
· Automatic Function: 9- seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
|
· ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
|
AED Mode
|
· Heart Rate: 20-300BPM.
|
· AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
|
· Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
|
· Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex
wave duration >=140ms. |
· Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
|
· Charge Control: Control on device front panel, press key on paddle.
|
Battery
|
· Prompts: Voice and visual prompts.
|
· Type: Rechargeable, Ni- MH battery, 12V.
|
Manual Mode
|
· Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum
|
· Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
|
energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect
|
· Synchronized Mode: Synchronizes defibrillator
|
pulse to patient’s
|
|
operating time with different functions
|
· R-wave. ”SYNC” message displayed on monitor
|