Professional CBCT X-ray
Multiple planar Reconstruction
Lateral Cephalometric Measurements
Implant Simulation
Metal Artifact Correction
3D Fine Reconstruction
Density Measurement
Image Slice for Implanting
Product Brochure:DOWNLOAD
- Introduction
- Parameter
Introduction
Professional CBCT X-ray YJ-QD4300
Multiple planar Reconstruction
Axial, coronal and sagittal slices can be observed simultaneously. Besides, the slice in any direction is available. Buccolingual slices, distal and mesial sections were obtained to facilitate diagnosis.
Lateral Cephalometric Measurements
In comparison to traditional two-dimensional cephalometric radiographs, lateral cephalograms on CBCT can better reflect the true craniofacial morphology. With higher accuracy in landmark point identification and line distance measurement, it can avoid the distortion of patient measurement data caused by superimposition, image blurring and facial asymmetry of two-dimensional anatomical structures.
Implant Simulation
It can evaluate the bone quality and bone quantity of the implant area, automatically outline the neural tube. Clarifying the relationship between the implant position and the adjacent anatomical structure to accurately select the implant position, the optimal length and diameter of the implant. It can improve the success rate, and avoid possible nerve or blood vessel damage.
Metal Artifact Correction
With the new T-MAR correction module for metal artifact removal, the system corrects metal artifacts intelligently. It avoids overmodification and saves the original clinical data.
3D Fine Reconstruction
The smallest voxel size reaches 0.05 mm, which is more suitable for the diagnosis of dental pulp disease.
Density Measurement
Visual assessment of bone quality, bringing greater convenience to dentists.
Image Slice for Implanting
It permits the evaluation of the overall osteogenesis and facilitates the macroscopic observation of the bone condition around implants.
Parameter
Model
|
3D-Plus
|
3D-Max
|
|
Field of View(mm*mm)
|
170*170
160*100
160*50
80*80
|
200*170
160*100
160*50
80*80
|
230*180
160*100
160*50
80*80
|
Voxel Size(mm)
|
0.3
0.25/0.125
0.2/0.1
0.125/0.0625
|
0.3
0.25/0.125
0.2/0.1
0.125/0.0625
|
0.3/0.15
0.25/0.125
0.2/0.1 0.125/0.0625 |
Spatial Resolution
|
2.4 lp/mm
|
2.2 lp/mm
|
|
Reconstruction Time
|
≤40s
|
≤40s
|
|
Tube Current
|
Min:2 mA Max: 10mA
|
||
Tube Voltage
|
Min: 60KV Max: 100KV
|
||
Scan Time
|
25/12.5/15.625/18.75s
|
12.5/12.5/15.625/18.75s
|
|
Focal Spot Size
|
0.5(IEC60336)
|
||
Sensor type
|
α-Si Flat panel detector
|
||
Sensor Size
|
16*16cm
|
26*21cm
|
|
Unit Dimensions
|
1825*1077*2109mm
|
||
Weight
|
340kg
|
||
Packing Size
|
Case1: 1930*800*1300mm 304KG
Case2: 1970*1270*1170mm 290KG
|
||
Power
|
Single-phase, AC220V/230V, ±10%, 10A, 50Hz/60Hz,±1Hz
|