* The tiny bodyis only 580mm
* One-click unlockingin case of no power
* Electric power assistin induction type
* One-hand push is supported

 

Product Brochure:DOWNLOAD

  • Introduction
  • Parameter

Introduction

Hospital Used High Frequency 50kw 500mA Digital X Ray Equipment Mobile Dr Xray Machine

01 Equipped With High Anode Heat Capacity Of X-Ray Tube And Large Outputpower Of High Frequency Generator

Which guarantee to continue emitting high quality x-rays, and easily meet the large number ofcontinuous exposures needs.

 
02 Innovative standby sleep modeIn standby mode,
it automatically enters hibernationwith energy storage mode, effectively extending thestandby time by more than 30%.
Parameter

Flat Panel Detector

- Detector technology: Wireless a -Si Flat Panel Detector
- Scintillator material: CsI
- Images size: 350mm x 430mm
- Static pixel matrix: 2500 x 3052pixels
- Effective pixels: 7.60million
- Pixel size: 140μm
- Spatial resolution: 3.5lp/mm
- Output grayscale: 16bit
- Acquisition time: ≤7s

High Frequency Generator

- Nominal output power: 32kW
- Max output power: 40kW
- Frequency: 50kHz/60kHz ± 1Hz
- kV range: 40~150kV, 1kV step
- mA range: 50 -400mA
- mAs range: 1~630mAs
- Power requirement: 220V

X-ray tube

- Focus: 0.6/1.2mm
- Voltage: 150kV
- Anode type: Rotating
- Anode heat capacity: 300kHU
- Anode angle: 12°


Mobile Stand

- The Vertical Movement Range of X -ray Tube Center along the Column: 580~1800mm
- The Telescopic Movement Range of X -ray Tube Center along the Column Side: 720~1220mm
- Stand Column Horizontal Rotation Range: ±315°
- Collimator Rotation Range along the vertical axis: ±90°
- Mobile Stand Size: 1230 × 580 × 1820 mm

Collimator

- Control: Manual
- Filter: 1.2mm Al
- Light: LED lamp

DX Ray Diagnostic Workstation

- Display size: 19inch
- Pixel matrix: 1280 x 1024pixels
- Patient Management: manual registration, WORKLIST automatic query.
- Image Acquisition: automatic window adjustment, automatic cropping, automatic transmission.
- Image Processing: image correction, image flipping.
- Image Observation: window width window level adjustment, image flipping, image rotation, image scaling, and restoration.
- Medical Record Report : automatic loading of patient information
- Film Printing: support DICOM3.0 standard laser camera printing.
- DICOM Transfer: send images to any PACS and workstation that complies with the DICOM 3.0 standard.

Other features

 

Dose control mode

- APR (Anatomically Programmed Radiography) mode
- Manually setting the exposure mode

Collision resistance

- Electrically assisted drive and has brake equipment
- Support switch to manual mode without power
- Slope assist system, maximum movement slope: ≤8 °

Interactive system

- Time -lapse exposure function
- Remote visual observation system and intercom system

Power management system

- Battery power display device
- Independent control system for power assist and high frequency generator exposure output
- Quick charging mode
- Power intelligent management system: computer sleep, high frequency generator sleep mode
- Intelligent power switching function: support exposure during charging