Usg Abdomen Sonography YJ-370T
.Main screen 15" medical HD monitor
.Flexible monitor bracket
.All-in-one keypad
·Detachable probe hanging slot
.Front double pull handle
.Flexible caster, directional locking
.One-piece body structure
Product Brochure:DOWNLOAD
- Introduction
- Parameter
Introduction
IMAGE PROCESSING FUNCTION --- PSEUDO COLOR
It is a way to change the display mode of black and white images into color display.
PSEUDO COLOR
Since the human eye is not very sensitive to the resolution of gray scale levels, the sensitivity of the human eye to differentecho intensities can be enhanced after the black and white images are converted to color. Subjectively, the dynamic range of thedisplay signal is increased, and the recognizability of the image boundary is enhanced.
It is a way to change the display mode of black and white images into color display.
PSEUDO COLOR
Since the human eye is not very sensitive to the resolution of gray scale levels, the sensitivity of the human eye to differentecho intensities can be enhanced after the black and white images are converted to color. Subjectively, the dynamic range of thedisplay signal is increased, and the recognizability of the image boundary is enhanced.
Parameter
Basic Parameters:
|
|
Probe Depth
|
16 levels
|
Probe Frequency
|
5 levels
|
Main gain
|
0-100%
|
8 TGC
|
adjustable
|
Focus
|
4
|
Image storage
|
4920 images
|
Pseudo color
|
0-7
|
Scanning area(angle)
|
3 levels
|
Edge enhancement
|
0-3
|
Linear correlation
|
0-5
|
Gamma correction
|
0-7
|
Frame correlation
|
0-3
|
Dynamic range
|
0-135
|
Cine loop
|
512 frames
|
Body mark
|
97 kinds
|
U Disk support
|
FAT32 format
|
Image reversal
|
up/down, left/right, black/white
|
Measurement
|
General measurement, GYN & OB measurement package, Andrology measurement , Cardiac measurement
|
OB-1
|
GS,BPD,CRL,FL,HL,TAD,LV,OFD,AC,HC,AFI
|
OB-2
|
FTA,TTD,APTD,THD,TCD,CI,EFW,Input LMP,Growth Curve
|
Various Probes
|
Convex probe (2.0 - 5MHz)
|
Linear probe (5.5 - 9.0MHz)
|
|
Trans-vaginal probe (5.0 - 8.5MHz)
|
|
Micro-convex probe (4.0 - 7.0MHz)
|
|
Probe frequency:
|
|
Convex probe
|
Frequency: 2.0MHz,2.5MHz,3.5MHz,4.0MHz,5MHz
Depth: 16 level 【126,142,158,173,189,197,205,213,221,229,237,245,253,261,269,307mm】 |
Linear probe
|
Frequency: 5.5MHz,6.5MHz,7.0MHz,7.5MHz,9.0MHz
Depth: 16 level 【35,42,49,62,69,76,83,90,97,104mm】 |
Trans-vaginal probe
|
Frequency: 5.0MHz,5.5MHz,6.5MHz,7.5MHz,8.5MHz
Depth: 16 level 【62,69,76,83,90,97,104,111,125,139mm】 |
Micro-convex probe
|
Frequency: 4.0MHz,4.5MHz,5.0MHz,6.5MHz,7.0MHz
|
Depth: 16 level 【62,69,83,97,111,125,139,152,166,180mm】
|